Pricelist of metrological services (calibration services)

General terms and conditions of metrology services and services of Assay Office

Listed prices are given without VAT

CodeServicePrice EUR
Time based tariff (one hour of working time)80
TIME AND FREQUENCY MEASUREMENT DEVICES
Additional point +20 % of main price
201030Time and frequency measures and measuring devices calibration 10-9U<10-6297
201050Time and frequency measures and measuring devices calibration 10-5U<10-3176
201070Signal generator calibration 0,01 Hz...1300 MHz (non-accredited up to 8 GHz)
(frequency measurement up to 10 points), 10-9U<10-8
275
201080Signal generator calibration 0,01 Hz...1300 MHz (non-accredited up to 8 GHz)
(frequency measurement up to 10 points), 10-7U<10-5
209
201130Signal generator bandwidth calibration (10 Hz...1 MHz, 0,1 mV…10 V),
service is applied additionally to service code 201070 or 201080
127
201120Attenuator calibration (1 Hz…2200 MHz, -67 dBm...+23 dBm),
non-accredited measurements
165
201150RF power meter calibration (DC...2,2 GHz, -67 dBm...23 dBm)
RF power supply calibration (DC...18 GHz, -30 dBm...+20 dBm; 9 kHz...6 GHz,
-67 dBm...23 dBm), non-accredited measurements
(one level at 5...7 frequencies and 5...7 levels at one frequency)
165
201140Oscilloscope calibration (horizontal and vertical scale - amplitude and period/frequency,
up to 2 channels, each additional channel +20 %)
198
201190Timers/stopwatches (mechanical) calibration (up to 3 points) U≥0,1 s 110
201210Timers/stopwatches (digital) calibration (up to 3 points) U≥0,05 s 143
201200Tachometer calibration (up to 5 points)132
201220Tachograph programmer calibration (output frequency, speed, W-factor and clock test)209
ELECTRICAL QUANTITIES MEASUREMENT DEVICES
VOLTAGE, CURRENT AND POWER MEASURES, SOURCES AND MEASURING DEVICES
Additional function/parameter/range +20 % of main price
202010DC voltage measures calibration (0,0001≤U<0,001) %, service of national measurement standard laboratory682
202050Voltage, current and power measures/sources/measuring instruments calibration
(includes up to 2 parameters with one range, up to 5 points in range)
275
1µV…1 kV/10 µA…10 A, DC…1 MHz (0,001≤U<0,005) %
202060Voltage, current and power measures/sources/measuring instruments calibration
(includes up to 2 parameters with one range, up to 5 points in range)
198
1µV…1 kV/10 µA…3 kA, DC...1 MHz (0,005≤U<0,1) %
202180Voltage, current and power measures/sources/measuring instruments calibration
(includes one parameter with one range, up to 5 points)
132
1µV…1 kV/10 µA…3 kA, DC…1 MHz (0,1≤U<1) %
202190High voltage source and kilovoltmeter (>1 kV) calibration
(one range, voltage and current, up to 5 points)
308
TRANSDUCER INDICATORS (electrical simulation of temperature, pressure etc.)
Additional function/range/channel/5 points +20 % of main price
203030Transducer indicator (with DC voltage, DC current or resistance input) calibration
(one function/range/channel, up to 5 points)
198
ELECTRICAL INSTALLATION AND SAFETY TEST EQUIPMENT
204060Safety test device ≤1 kV (up to 2 functions) calibration176
204110Combined test device calibration (includes 3 functions ≤1 kV and one range >1 kV)352
204064Additional parameter of the function, applied with 204060 or 204110. Price code is applied when the number of parameters in each measuring function is greater than 233
204062Safety test device ≤1 kV calibration, each next function, applied with 204060, 20411055
204112Safety test device calibration, each next function >1 kV, applied with 20411066
204070ESD device calibration (Wrist Strap, Footwear Test Station etc.), voltage indicator calibration, one function132
204130Spark tester calibration (voltage, short circuit current, spark tester sensitivity,
according to IEC 62230)
462
204140Spark tester each additional module calibration (applied with 204130)94
RESISTANCE MEASURES AND MEASURING DEVICES
Additional range +20 % of main price
206070Resistance measure (10-3...104) Ω calibration, one value, (1≤U<5) µΩ/Ω, service of national measurement standard laboratory506
206080Resistance measure (10-3 ... 108) Ω calibration, one value, (0,001≤U<0,01) % 182
206120Resistance measures and measuring devices (10-3 ... 1010) Ω calibration, 1 range
(0,01≤U<0,05) %
253
206100Resistance measures and measuring devices (10-4 ... 4010) Ω calibration, 1 range
(0,05≤U<0,5) %
176
MULTIMETERS/CURRENT CLAMPS
Multimeter calibration includes DC & AC voltage, DC & AC current and DC resistance calibration. Calibration guide: Euramet cg-15. Additional function +20 % of main price (frequency, capacity etc.)
211302Multimeter (7 or above numerical places, maximum reading over 8999999 counts) calibration605
211330Multimeter (6 numerical places, maximum reading 8999999 counts) calibration352
211340Multimeter (5 numerical places or maximum reading 199999) calibration319
211370Multimeter (4 numerical places, maximum reading 19999) calibration264
211310Multimeter (up to 3 numerical places, maximum reading 1999) calibration187
211320Multimeter calibration, one function (DC or AC current, DC or AC voltage or DC resistance) (0,005≤U<0,1) % 165
211380Current clamp calibration (current)165
211390Current clamp calibration (up to 4 numerical places, current, voltage, resistance)253
211200Scope meter (incl. vehicle diagnostic tester) calibration (DC voltage, AC voltage and DC resistance up to 2 inputs; DC current, AC current with one measuring probe; horizontal and vertical scale of oscilloscope up to 2 channels/probes)396
211210Scope meter (incl. vehicle diagnostic tester) calibration, additional parameter (e.g. frequency)/
input/probe (e.g. current clamp). Applied with 211200
77
CAPACITANCE, INDUCTANCE AND AC RESISTANCE MEASURES AND MEASURING DEVICES
Additional measuring function +20 % of main price.
Inductance - field of non-accredited calibration
221024Capacitance and resistance (measures) calibration132
221044LCR-meter (resistance, capacitance) calibration (0,05≤U<0,5) % 253
221034LCR-meter and AC bridge calibration (0,005≤U<0,05) % 385
ELECTRICAL CONDUCTIVITY MEASURES
Additional frequency +20 % of main price
221050Electrical conductivity standard calibration at 2 frequencies (1,0...59,5) MS/m,
(60; 120; 240; 480) kHz, (0,6≤U˂1,4) %
193
221051Electrical conductivity standard calibration at 2 frequencies, incl. measurement of temperature coefficient (1,0...59,5) MS/m, (60; 120; 240; 480) kHz, (0,6≤U˂1,4) %270
MEASUREMENT DEVICES FOR PHYSICAL-CHEMICAL QUANTITIES
Additional point, range, parameter etc +20 % of main price, excl. sound level meters
Device with voltage/current output +20 % of main price
207054Hygrometer calibration (up to 3 humidity points at one temperature)120
207055Thermohygrometer calibration (3 temperature points + 3 humidity points at one temperature)150
207056Thermohygrometer with data logger calibration (3 temperature points + 3 humidity points at one temperature)175
207060Climatic chamber calibration (one temperature, one relative humidity)165
207061each additional temperature or relative humidity (applied with 207060)55
207062each additional measuring location (applied with 207060)33
207114pH-meter calibration (3 points, pH 4; 7 and 9,21)125
207230Sound level meter calibration, 1 frequency weighting (A or C), 4 frequencies
(31,5 Hz; 125 Hz; 1 kHz; 8 kHz) and 3 levels (94 dB; 104 dB; 114 dB)
110
207270Sound level meter calibration, additional frequency weighting (A or C, same frequencies and levels) or additional frequency (3 levels), applied with 20723045
207280Sound level meter conformity assessment/calibration (according to EVS-EN 61672-1:2013, acoustical method)242
218010Areometer / Density meter calibration (up to 3 points, range 650 kg/m3...1850 kg/m3,
U≥0,1 kg/m3; includes one temperature point for the areometer with incorporated thermometer)
215
218020Density meter calibration using CRMs (water density at 3 temperature + 1 density at one temperature in the range 692 kg/m3...1622 kg/m3, U≥0,1 kg/m3)264
218030Additional density using CRMs, applied with 218020110
218050Alcoholometer calibration (up to 3 points; includes one temperature point for the alcoholometer with incorporated thermometer)231
207240Dissolved oxygen meter calibration (up to 3 points)205
207250Electrical conductivity meter calibration, range 84 µS/cm...24,80 mS/cm (up to 5 points)215
207251Electrical conductivity meter calibration, additional point in range (14,94...84) µS/cm, applied with 207250, price depends on the selected calibration point
207260Breath analyzer (exclud. evidential breath analyzers) calibration (3 points)40
207300CO2 meter calibration (up to 3 points), range (200...10000) ppm165
FORCE AND TORQUE MEASUREMENT DEVICES
Additional point +10 % of main price
208014Force gauges and transducers up to 1 kN calibration (up to 5 points) U≥0,1 %145
208024Force gauges and transducers up to 50 kN calibration (up to 5 points) U≥0,1 %220
208130Force gauges and transducers over 50 kN calibration (up to 5 points) U≥0,1 %396
208150Force transducers up to 50 kN calibration, mV/V output (up to 10 points) U≥0,1 %363
208044Dynamometric (torque) wrench up to 400 Nm calibration (up to 5 points) U: (0,3...0,5) % 70
208054Dynamometric (torque) wrench over 400 Nm and up to 1 kNm calibration (up to 5 points)
U: (0,3...0,5) %
99
208045Dynamometric (torque) wrench with digital readout or with specific adapter, up to 400 Nm calibration (up to 5 points) U: (0,3...0,5) % 99
208055Dynamometric (torque) wrench with digital readout or with specific adapter, over 400 Nm and up to 1 kNm calibration (up to 5 points) U: (0,3...0,5) % 125
208056Dynamometric (torque) wrench over 1 kNm and up to 3 kNm calibration (up to 5 points)
U≥1 %
160
208140Pull-, and pressure testers and testing machines up to 1 kN calibration (up to 5 points)
U≥0,03 %
264
208064Presses and testing machines over 1 kN and up to 2 MN calibration (up to 5 points)
U: (0,03…0,15) %
360
208114Torque tester <20 Nm calibration (up to 5 points) U≥0,5 %220
208104Torque tester (20…400) Nm calibration (up to 5 points) U≥0,3 %319
208105Torque tester over 400 Nm calibration (up to 5 points) U≥0,3 %396
208124Vehicle brake testers calibration (braking force and vehicle weight parameters, up to 5 points each parameter)344
VOLUME MEASUREMENT DEVICES
Additional filling mark, flow +20 % of main price
209010Volumetric glassware calibration (measuring cylinders and volumetric flasks, up to 3 filling marks)80
209130Piston pipette calibration (up to 2 filling marks)73
209115Fuel dispenser calibration (max flow ≤130 l/min)90
209120Liquid meter calibration on site (one flow Q< 30 m3/h) U: (0,1...0,5) %210
209125Measuring system/liquid meter (for oil products) calibration (max flow >200 l/min)440
MASS MEASUREMENT EQUIPMENT
Additional point +10 % of main price. Additional tests (determination of minimum weight, additional tests with tare etc.) +50 % of main price. Calibration of weights - the price for single weight
210340Weight E2 (1 mg…50 kg) calibration, service of national measurement standard laboratory110
210020Weight F1 (1 mg…1 kg) calibration66
210050Weight F1 (2 kg...50 kg) calibration, service of national measurement standard laboratory88
210030Weight F2 (1 mg...20 kg) calibration40
210040Weight M1 (1 mg...5 kg) calibration35
210150Weight M1 over 5 kg and up to 50 kg calibration47
210180Non-automatic weighing instruments, class I calibration (up to 10 points) U: (0,01...20) mg185
210190Non-automatic weighing instruments, class II up to 30 kg calibration (up to 10 points)
U: (0,1...200) mg
115
210270Non-automatic weighing instruments, class II, over 30 kg and up to 200 kg calibration
(up to 10 points)
200
210210Non-automatic weighing instruments, class III up to 200 kg calibration (up to 10 points)
U: (0,3...10) g
90
210230Non-automatic weighing instruments, class III up to 500 kg calibration (up to 5 points) U: (4...12) g 145
210240Non-automatic weighing instruments, class III up to 2 t calibration (up to 5 points) U: (12...50) g265
210250Non-automatic weighing instruments, class III up to 5 t calibration (up to 5 points) U: (50...100) g360
210260Crane scale calibration (over 5 t and up to 50 t) (up to 5 points)400
LENGTH MEASUREMENT DEVICES
Additional point, range, parameter etc. +10 % of main price
212070Dial indicator; inner, depth and thickness gauge with dial indicator calibration (up to 10 points)
U: (2...50) µm
77
212120Micrometer (0...25) mm calibration (up to 5 points) U: (2...4) µm39
212130Micrometer (25...100) mm calibration (up to 5 points) U: (2...5) µm49
212140Micrometer >100 mm; inside- and depth-micrometer and micrometer head calibration
(up to 5 points) U: (2…30) µm
59
212162Inside micrometer head (<200 mm) calibration U: (2…5) µm59
212163Inside micrometer head (≥200 mm…<600 mm) calibration U: (2…15) µm88
212168Inside micrometer head (≥600 mm…1000 mm) calibration U: (15…30) µm132
212167Micrometer setting measures and extension rods calibration base price, applied when submitted to calibration without micrometer, as standalone gauge; applied with 212145-212161, 212164-21216653
212164Inside micrometer extension rods up to 50 mm calibration U: (2...5) µm29
212165Inside micrometer extension rods up to 500 mm calibration U: (2…10) µm44
212166Inside micrometer extension rods up to 1000 mm calibration U: (12…30) µm66
212145Micrometer setting measures up to 100 mm calibration U: (1...5) µm27
212150Micrometer setting measures up to 500 mm calibration U: (1...5) µm33
212160Micrometer setting measures (>500…1000) mm calibration U: (3…15) µm50
212161Micrometer setting measures >1000 mm calibration U: (15…30) µm65
212180Three-point inside micrometer up to 200 mm calibration (at least 2 points) U: (2…4) µm83
212270Measuring tape/dip tape up to 5 m calibration (up to 5 points) U: (0,2...0,3) mm52
212290Measuring tape/dip tape (>5...20) m, calibration (up to 5 points) U: (0,2...0,8) mm97
212305each next 20 m calibration, for measuring tape/dip tape (>20...120) m, applied with 21229040
212260Ring gauge/setting ring, plug gauge, diameter up to 60 mm, calibration
diameter in one direction U: (0,6...1,2) µm
66
212265Ring gauge/setting ring, plug gauge, diameter (>60…290) mm, calibration
diameter in one direction U: (1,0…2,0) µm
84
212280Ring gauge/setting ring, plug gauge calibration
roundness deviation at three heights U: (0,3...1) µm, applied with 212260 or 212265
48
212060Thread plug gauge calibration (pitch diameter) U: (3…5) µm 60
212062Thread ring gauge calibration (pitch diameter) U: (3…5) µm 66
212061Thread gauge calibration (pitch diameter, both sides of thread plug gauge GO/NOTGO)
U: (3...5) µm
80
212330Caliper (0...200) mm calibration (up to 5 points) U: (0,02...0,2) mm32
212340Caliper (0...1000) mm; height-, depth- and inside calipers calibration (up to 5 points)
U: (0,02...0,2) mm
44
212350Caliper (0...2000) mm calibration (up to 5 points) U: (0,02...0,2) mm73
212310Dial indicators and measuring heads, with scale division ≤1 μm calibration (up to 10 points)
U: (0,6...2,0) µm
116
212250Ruler calibration (scale division ≥1 mm, up to 5 points) U: (0,2...0,3) mm39
212320Measuring wheel calibration U: (0,5…2) %130
212720Cable length measuring device calibration U: (0,2...1,5) %154
212730Cable measurement device on-site calibration U : (0,2...1,5) %230
212530Sieve calibration, diameter up to 200 mm (number of apertures measured according to table 4
in EVS-ISO 3310-1:2017, "compliance and inspection"), aperture (4...125) mm U: (0,03…0,10) mm
60
212531Sieve calibration, diameter up to 200 mm (number of apertures measured according to table 4
in EVS-ISO 3310-1:2017, "compliance and inspection"), aperture (0,4...3,55) mm U: (5…8) μm
72
212532Sieve calibration, diameter up to 200 mm (number of apertures measured according to table 4
in EVS-ISO 3310-1:2017, "compliance and inspection"), aperture (45...355) μm U: (3…5) μm
90
212535Sieve calibration, diameter up to 200 mm (EVS-ISO 3310-1:2017 in 5.3.2.3, "calibration"), aperture (4…125) mm U: (0,03…0,10) mm96
212540Sieve calibration, diameter up to 200 mm (EVS-ISO 3310-1:2017 in 5.3.2.3, "calibration"), aperture (0,4…3,55) mm U: (5…8) μm105
212545Sieve calibration, diameter up to 200 mm (EVS-ISO 3310-1:2017 in 5.3.2.3, "calibration"), aperture (45…355) μm U: (3…5) μm166
212546Sieve calibration, diameter >200 mm, additional fee +20% (applied with 212530, 212531, 212532, 212535, 212540, 212545)
212570Ultrasonic thickness gauges and coating thickness gauges (one range, Fe or NFe) calibration
(up to 5 points) U: (1…200) µm
105
212571Coating thickness gauges (two ranges, Fe + NFe) calibration (up to 5 points)
U: (1…200) µm
130
212600Laser distance meters calibration (up to 5 points) U: (1…5) mm99
212580Measuring microscope calibration, up to two scales (each additional scale +20 %) U: (1...21) µm
Non-accredited calibration
264
212170Reading microscope calibration (up to 5 points) U : (3...20) µm
Non-accredited calibration
73
212380Angle gauge/protractor calibration (up to 5 points) U: 15’’…30’60
212360Square (deviation from vertical line, arm length up to 750 mm) calibration (up to 5 points)
U: (5…50) µm
79
212470Level (one surface, one bubble) and inclinometer, scale division >0,01°, calibration
U: (0,2...0,5) mm/m
Additional scale +20 %
66
212480Level and inclinometer calibration, scale division ≤0,2 mm/m or ≤0,01° (up to 5 points)
U: (0,005...0,2) mm/m
126
212490Laser level calibration (horizontal line in two directions, check of detector if available)
Non-accredited calibration
178
212520Straight edge, flat straight edge calibration (one surface)
Additional surface +60 % of main price
Non-accredited calibration
119
212390Vehicle accelerometer and decelerometer calibration (0...9,81) m/s2, U = 0,02 m/s2 ,
devices with static calibration regime
130
212500Surface plate flatness calibration, Moody's method (side length up to 1000 mm)
Non-accredited calibration
330
212510Welding gauge calibration (up to three scales, each additional scale +20 % of main price)
Non-accredited calibration
80
212610Gauge block calibration base price for class K and 0 (additional unit price according to class and range), service of national measurement standard laboratory132
212611Gauge block calibration unit price, class K and 0, (0,5…100) mm, U≥[0,0542+(0,91×L)2]½ µm, service of national measurement standard laboratory39
212612Gauge block calibration unit price, class K and 0, (>100…500) mm, U≥[0,282+(1,2×L)2]½ µm, service of national measurement standard laboratory66
212660Gauge block calibration base price for class 1 and 2 (additional unit price according to class and range)66
212620Gauge block calibration unit price, class 1 and 2, (0,5...100) mm, U≥(0,07+0,6×L) µm 26
212650Gauge block calibration unit price, class 1 and 2, (>100…1000) mm, U≥(0,2+2×L) µm 57
212550Feeler gauge, radius gauge, pin gauge calibration base price (additional unit price will be added, code 212560)53
212560Feeler gauge, radius gauge, pin gauge calibration, unit price.
Applied with 212550
9
PRESSURE MEASUREMENT DEVICES
Additional point etc. +20 % of main price; time based tariff applies if Metrosert must dismount pressure gauge for calibration. If Metrosert has to install a data logging software on computer, time based tariff applies (min 30 minutes).
213070Pressure gauge accuracy class ≥1,0 calibration (analog readout, up to 70 MPa, up to 5 points)
U≥0,2 % (in case of conformity assessment - the expanded uncertainty of measurements is not taken into account in the statement of conformity)
48
213350Pressure gauge accuracy class ≥1,0 calibration (analog readout, ≥70 MPa, up to 5 points) U≥0,2 % (in case of conformity assessment - the expanded uncertainty of measurements is not taken into account in the statement of conformity)96
213080Tyre pressure gauge, oxygen pressure gauge and pressure gauge with digital readout accuracy class ≥1,0 calibration (up to 5 points) U≥0,2 %69
213310Pressure gauge accuracy class >0,1…<1,0 (including also devices with relative scale, digital and analog readout, sensors with indicator, loggers, differential pressure gauges), range >25 kPa
(250 mbar, 3,5 psi) calibration (up to 5 points) 0,05 %≤U≤0,2 %
135
213130Micromanometer calibration (up to 3 points, range 5 Pa…25 kPa) U≥0,2 Pa135
213240Pressure transducer (voltage/current output) accuracy class >0,1 calibration (up to 5 points, incl. zero) 0,05 %≤U≤0,2 %170
213250Pressure reference standard (exclud. pressure balances), accuracy class ≤0,1 calibration (up to 5 points) 0,01 %≤U≤0,05 %308
213330Barometer calibration, range (950…1050) hPa (up to 3 points) U≥0,2 hPa165
213340Absolute pressure gauge calibration (up to 3 points), range (3…200) kPa abs
0,05 %≤U≤0,2 %
230
213220Pressure balances piston-cylinder assembly (0...70) MPa calibration (effective area determined at 5 pressures) 0,01 %≤U≤0,05 %700
213260Non-automatic sphygmomanometer calibration/conformity assessment (e.g. according to requirements stated in EVS-EN ISO 81060-1:2012) (6...7 points) U≥0,2 %
The expanded uncertainty of measurements is not taken into account in the statement of conformity
48
213270Automatic and semi-automatic blood pressure monitor calibration (up to 3 systolic-diastolic pressure ranges) U≥0,3 kPa (2 mmHg)
Non-accredited calibration
40
TEMPERATURE MEASUREMENT DEVICES
Additional point +20 % of main price, except 214140 - temperature chambers, furnaces and freezers
214150Resistance thermometers (Pt) calibration at the fixed points (Hg, H20, Ga, Sn, Zn) main price
0,003 °C≤U<0,006 °C (includes calibration at one fixed point), service of national measurement standard laboratory
275
214151additional temperature at the fixed point (Hg, H20, Ga, Sn, Zn), applied with 214150, service of national measurement standard laboratory220
214160Thermometers Pt (-196…+400) °C calibration base price 0,008 °C≤U<0,08 °C, service of national measurement standard laboratory275
214161each calibration point, applied with 214160, service of national measurement standard laboratory80
214084Thermometers (-196…+300) °C, d≤0,1 °C, calibration (up to 3 points) 0,04 °C≤U<0,16 °C220
214086Liquid-in-glass thermometers (-80…+300) °C, scale division ≤0,1 °C, calibration (up to 3 points)
0,04 °C≤U<0,16 °C
220
214010Liquid-in-glass thermometers (-40…+300) °C, scale division <0,5 °C, calibration (up to 3 points)170
214015Infrared thermometers (-30…+300) °C calibration (up to 3 points)135
214020Thermographic instrument (-15…+500) °C calibration (up to 5 points), service of national measurement standard laboratory440
214080Thermometers (-40…+400) °C (scale division/d≥0,1 °C) calibration (up to 3 points)100
214085Surface temperature probes, thermometers with surface probe (-25…+350) °C calibration (up to 3 points)150
214090Temperature data loggers (-40…+400) °C calibration (up to 3 points)125
214095Determination of time recording error of temperature data logger, applied with 21409040
214110Resistance thermometers, thermocouples (-40…+400) °C calibration (up to 3 points)145
214120Thermocouples (+400…+1100) °C calibration (up to 3 points)200
214140Temperature chambers, furnaces, freezers (-80…+1100) °C calibration (one temperature, one measuring location)155
214141each additional temperature, applied with 21414055
214142each additional measuring location, applied with 21414033
214180Temperature block calibrators (-40…+1100) °C calibration (up to 5 points)330
MEASUREMENT DEVICES FOR OPTICAL QUANTITIES
Additional point, wavelength etc. +20 % of main price
207024Spectrophotometer, photocolorimeter calibration (up to 3 wavelengths)195
207154Refractometer calibration (up to 5 points)135
207222Window-(light)transmittance meter calibration (up to 5 points)95
217010Luxmeter calibration (up to 10 points), (15…5000) lx190
217040Optical filter calibration. For neutral density filter up to 3 wavelengths. For spectral filter peak wavelength values in range (250...900) nm 165
217020Smoke opacity meter calibration (up to 5 points + check with the light beam unblocked/blocked)125
217030Colour meter calibration/surface colour measurement, colour coordinates X, Y, Z or L*, a*, b*
0≤X, Y, Z≤100 (0,6≤U˂20)
230
LIQUID FLOW MEASURING DEVICES
Additional point etc. +20 % of main price
Device with voltage/current output +20 % of main price
219050Flowmeter DN(15…40), t= (15...30) °C, Q = (0,006…25) m3/h calibration with water
(up to 3 points) U≥0,4 %
242
219060Flowmeter DN(50…100), t= (15...30) °C, Q = (0,3…250) m3/h calibration with water
(up to 3 points) U≥0,5 %
300

Listed prices are given without VAT